Comparison table of the relationship between valve size and medium velocity

Column:Technical article Time:2019-06-22
It is well known that the flow rate and velocity of the valve mainly depends on the size of the valve, but also with the valve structure type of the resistance to the medium...

It is well known that the flow rate and flow rate of the valve mainly depends on the size of the valve, and the valve structure type of the resistance to the medium, at the same time with the pressure of the valve, temperature and the concentration of the medium and other factors have a certain internal relationship.Valve flow area and flow velocity, flow rate has a direct relationship, and flow rate and flow are interdependent two quantities.When the flow rate is constant, the flow rate is large, the flow area can be smaller;Small velocity, the flow area can be larger.On the contrary, the flow area is large and the velocity is small.The runner area is small and the velocity is high.

 

1, the flow rate of the medium is large, the valve diameter can be small, but the resistance loss is large, the valve is easy to damage.High flow rate, the flammable and explosive media will produce electrostatic effect, resulting in danger;The flow rate is too small, inefficient, and uneconomical.For high viscosity and explosive medium, should be a small flow rate.The flow rate of oil and liquid with high viscosity is selected according to the viscosity, generally 0.1 ~ 2m/s.

2. Generally speaking, the flow rate is known and the flow rate can be determined by experience.Nominal size of valve can be calculated by flow rate and flow rate.

3, the valve size is the same, its structure is different, fluid resistance is not the same.Under the same conditions, the greater the resistance coefficient of the valve, the more fluid flow through the valve velocity, flow rate drop;The smaller the valve resistance coefficient is, the less the flow rate and flow rate decreases through the valve.

 

Common flow rates of various media are shown in the following table:

Fluid nameConditions of use
Velocity(m/s)
Saturated steam
DN>200
DN=200~100
DN<100
30~40
25~35
15~30
Superheated steam
DN>200
DN=200~100
DN<100
40~60
30~50
20~40
Low pressure steamρ<1.0(Absolute pressure)15~20
Medium pressure steamΡ=1.0~4.0(Absolute pressure)20~40
High pressure steamΡ=4.0~12.0(Absolute pressure)40~60

Compressed gas
Vacuum
Ρ≤0.3(Gage pressure)
Ρ=0.3~0.6(Gage pressure)
Ρ=0.6~1.0(Gage pressure)
Ρ=1.0~2.0(Gage pressure)
Ρ=2.0~3.0(Gage pressure)
Ρ=3.0~30.0(Gage pressure)
5~10
8~12
10~20
10~15
8~12
3~6
0.5~3
oxygen
Ρ=0~0.05(Gage pressure)
Ρ=0.05~0.6(Gage pressure)
Ρ=0.6~1.0(Gage pressure)
Ρ=1.0~2.0(Gage pressure)
Ρ=2.0~3.0(Gage pressure)
5~10
7~8
4~6
4~5
3~4
Gas 2.5~15
Semi water gasΡ=0.1~0.15(Gage pressure)10~15
Natural gas 30
NitrogenΡ=5~10(Absolute pressure)15~25

ammonia
vacuum
Ρ<0.3(Gage pressure)
Ρ<0.6(Gage pressure)
Ρ≤2(Gage pressure)
15~25
8~15
10~20
3~8
Acetylene water 
30
5~6
Acetylene water
ρ<0.01(Gage pressure)
ρ<0.15(Gage pressure)
ρ<2.5(Gage pressure)
3~4
4~8
5
chlorine
Gas
liquid
10~25
1.6
氯化氫
氣體
液體
20
1.5
Liquid ammonia
Vacuum
Ρ≤0.6(Gage pressure)
Ρ≤2.0(Gage pressure)
0.05~0.3
0.3~0.8
0.8~1.5

Sodium hydroxide
Concentration 0~30%
Concentration 30%~505
Concentration 50%~73%
2
1.5
1.2
Sulfuric acid
Concentration 88%~93%
Concentration 93%~100%
1.2
1.2
HCl 1.5
Water has a similar viscosity to liquids
Ρ=0.1~0.3(Gage pressure)
Ρ≤1.0(Gage pressure)
Ρ≤8.0Gage pressure)
Ρ≤20~30(Gage pressure)
Heat network circulating water, cooling water
0.5~2
0.5~3
2~3
2~3.5
0.3~1
Water has a similar viscosity to liquidsPressure backwater0.5~2
Water has a similar viscosity to liquidsNo pressure backwater0.5~1.2

Tap water
DirectorΡ=0.3(Gage pressure)
BranchΡ=0.3(Gage pressure)
1.5~3.5
1~1.5
Boiler feed water >3
Steam condensate 0.5~1.5
CondensateGravity0.2~0.5
Hot water 2
Sea water, slightly alkaline water
Ρ<0.6(Gage pressure)
1.5~2.5

Note: the unit of DN value is mm;Ρ value unit is: MPa.


Examples:
 

The resistance coefficient of gate valve is small, only within the range of 0.1 ~ 1.5.Gate valve with large diameter, the resistance coefficient is 0.2 ~ 0.5;Shrinkage gate valve resistance coefficient is larger.

 

The resistance coefficient of globe valves is much larger than that of gate valves, generally between 4 and 7.Y-type globe valve (direct flow) has a small resistance coefficient between 1.5 and 2.Forged steel globe valve resistance coefficient is large, even up to 8.

 

The resistance coefficient of the check valve depends on the structure: swing check valve is usually about 0.8 ~ 2, in which the multi-lobe swing check valve has a larger resistance coefficient;Lift check valve resistance coefficient, up to 12.

 

Plug valve resistance coefficient is small, usually about 0.4 ~ 1.2.

 

The resistance coefficient of diaphragm valve is generally around 2.3.

 

Butterfly valve resistance coefficient is small, generally within 0.5.

 

Ball valve resistance coefficient is small, generally around 0.1.

 

Remark: the resistance coefficient of the valve is the value when the valve is fully open.

 

The selection of valve size should take into account the machining accuracy and dimension deviation of the valve, as well as other factors.Valve size should be adequate, generally 15%.In practice, the size of the valve varies with the size of the process line.


Knowledge: valve size and inch comparison table valve size (DN) and diameter comparison table


主站蜘蛛池模板: 国产一线av| 亚洲va在线va天堂xx xx| 欧美吻胸吃奶大尺度| 色视频2| 影音先锋每日av色资源站| 国产精品久久久久久久久动漫| 日本熟妇色xxxxx欧美老妇| 国产精品大全| 中老年熟妇激情啪啪大屁股| 少妇av一区二区三区无码| 成年人黄色片| 成人亚洲国产精品一区不卡 | 亚洲精品成人片在线观看| 色视频在线观看免费| 中文 在线 日韩 亚洲 欧美| 亚洲欧美黄色片| 精品国模一区二区三区| 二级大黄大片高清在线视频| 久久99精品久久久久久hb无码| 校园激情亚洲| 中文字幕成人精品久久不卡| 老司机激情影院| 国内露脸中年夫妇交换| 91av导航| 国产精品国产三级国产专区53| 国产人妻熟女ⅹxx高跟丝袜写真| 强辱丰满人妻hd中文字幕| 动漫精品中文无码通动漫| 久久99精品国产99久久6尤物| 亚洲欧美高清一区二区三区| 丰满少妇人妻无码专区| 亚洲成av人片久久| www91色com| 国产伦子沙发午休系列资源曝光| 久久久妇女国产精品影视| 无码人妻av一区二区三区蜜臀| www网站在线观看| 台湾精品一区二区蜜桃|